Back to Fluid Compatibility

Ammonium Chloride 1%

Data is at 70°F (21°C) unless otherwise noted in the chemical name.

Metal

13 materials
MaterialRatingMeaning
AluminumCFair to Poor — moderate/severe effect, evaluate carefully
Carbon SteelNo data — the source publishes no rating for this pair. Not a compatibility claim; verify independently.
Cast/Ductile IronDNot recommended — unsatisfactory / do not use
304 Stainless SteelCFair to Poor — moderate/severe effect, evaluate carefully
316 Stainless SteelNo data — the source publishes no rating for this pair. Not a compatibility claim; verify independently.
Hastelloy CAExcellent — fully compatible
BrassDNot recommended — unsatisfactory / do not use
Alloy 20BGood — minor effect, generally suitable
Alloy 40 (Monel)BGood — minor effect, generally suitable
TitaniumAExcellent — fully compatible
Duplex 2205, Cd4MCuNo data — the source publishes no rating for this pair. Not a compatibility claim; verify independently.
XM-19 Spring SteelNo data — the source publishes no rating for this pair. Not a compatibility claim; verify independently.
410 Stainless SteelNo data — the source publishes no rating for this pair. Not a compatibility claim; verify independently.
Legend:AExcellentBGoodCFair to PoorDNot recommendedNo data

Important Engineering Disclaimer:
Compatibility data is a preliminary screening guide only. Verify against actual concentration, operating temperature and pressure, fluid impurities, velocity/erosion, corrosion allowance, gasket seating stress, mechanical seal arrangement, vendor recommendations, applicable code, project specification, and the current Safety Data Sheet before engineering use. Ratings reflect Graco Chemical Compatibility Guide (Updated 10/29/2024) and are not a current SDS/GHS classification.