Back to Fluid Compatibility

Hydrocyanic Acid

Data is at 70°F (21°C) unless otherwise noted in the chemical name.

Metal

13 materials
MaterialRatingMeaning
AluminumAExcellent — fully compatible
Carbon SteelDNot recommended — unsatisfactory / do not use
Cast/Ductile IronDNot recommended — unsatisfactory / do not use
304 Stainless SteelBGood — minor effect, generally suitable
316 Stainless SteelAExcellent — fully compatible
Hastelloy CDNot recommended — unsatisfactory / do not use
BrassDNot recommended — unsatisfactory / do not use
Alloy 20CFair to Poor — moderate/severe effect, evaluate carefully
Alloy 40 (Monel)CFair to Poor — moderate/severe effect, evaluate carefully
TitaniumAExcellent — fully compatible
Duplex 2205, Cd4MCuDNot recommended — unsatisfactory / do not use
XM-19 Spring SteelDNot recommended — unsatisfactory / do not use
410 Stainless SteelDNot recommended — unsatisfactory / do not use
Legend:AExcellentBGoodCFair to PoorDNot recommended—No data

Important Engineering Disclaimer:
Compatibility data is a preliminary screening guide only. Verify against actual concentration, operating temperature and pressure, fluid impurities, velocity/erosion, corrosion allowance, gasket seating stress, mechanical seal arrangement, vendor recommendations, applicable code, project specification, and the current Safety Data Sheet before engineering use. Ratings reflect Graco Chemical Compatibility Guide (Updated 10/29/2024) and are not a current SDS/GHS classification.