Insulation Material Data

Insulation Material Data

Compare thermal and service limits, moisture and compressive behavior, planning thickness, jacketing compatibility, personnel protection and CUI risk.

Quick material profile

Explore temperature ranges and thermal properties.

Typical Services

HotPersonnel protectionNon-combustible

Operating Temperature Range

-18°C to 650°C

-273°C0°C+1200°C

Thermal Cond. (k)

0.040

W/m·K @ 100°C

Density

100

kg/m³ (Nominal)

Standard

ASTM C547

Material Spec.

Filter by service
Units

Thermal and service reference data

Showing 11 of 11 materials

Piping insulation material thermal and service reference data
Familyk ref (°C)FireServiceMaterial standardReference note
Aerogel BlanketFlexible blanket0.020100-200650150Non-combustible
HotColdCryogenicPersonnel protection
ASTM C1728Low conductivity and thin profile; verify grade-specific temperature range.
Phenolic FoamRigid foam0.02125-18015040Combustible
ColdCryogenic
ASTM C1126Low conductivity with generally low flame-spread and smoke; verify grade fire performance and corrosion compatibility.
Polyurethane Foam (PUF)Rigid foam0.02525-20012040Combustible
ColdCryogenic
ASTM C591Closed-cell cold-service insulation; confirm fire, vapour-barrier and temperature requirements.
Polyisocyanurate (PIR)Rigid foam0.02625-18015045Combustible
ColdCryogenic
ASTM C591Rigid closed-cell foam for cold and cryogenic service; requires effective vapour barrier and fire review.
FiberglassFibrous0.03525-445048Non-combustible
HotPersonnel protection
ASTM C547Typical screening preset for fibrous pipe insulation; verify product classification.
Elastomeric Foam (NBR)Flexible closed-cell0.03625-5011055Combustible
Cold
ASTM C534Flexible closed-cell foam with built-in vapour resistance; common for chilled-water and condensation control. Confirm flame-spread and smoke limits.
Mineral WoolFibrous0.040100-18650100Non-combustible
HotPersonnel protection
ASTM C547Preformed mineral-fibre pipe insulation; protect from moisture and weather exposure.
Cellular GlassRigid closed-cell0.04525-268427120Non-combustible
HotColdCryogenic
ASTM C552Closed-cell, low water-vapour permeability; suits cold and cryogenic service where moisture ingress must be controlled.
Expanded PerliteRigid inorganic0.0551000650190Non-combustible
HotPersonnel protection
ASTM C610Common hot-service rigid insulation; protect against water ingress.
Calcium SilicateRigid inorganic0.06010027927240Non-combustible
HotPersonnel protection
ASTM C533High compressive strength; common at supports and high-temperature service.
Ceramic FiberFibrous refractory0.10040001200128Non-combustible
HotPersonnel protection
ASTM C892Refractory fibre blanket for very high-temperature service; conductivity rises steeply with mean temperature.

Design, moisture and CUI guidance

Planning ranges organize the design study; they do not replace heat-transfer, condensation, support-load or fire calculations.

Insulation design, moisture, strength, jacketing and CUI screening data
MaterialWater / moistureCompressive behaviorPlanning thicknessJacketing / barrierCUI riskReference edition
Aerogel BlanketMany grades are hydrophobic but not waterproof; verify aging and immersion performance.Flexible and resilient; point-load capacity is system dependent.1050 mmThin-profile planning range; use certified k-curve in the design calculation.Aluminium · Stainless steel · Flexible weather barrier where qualifiedMediumHydrophobicity may reduce wetting, but seams, contamination and damaged jacketing still permit CUI.Verify active project edition
Phenolic FoamGrade and facing dependent; cut edges and joints require sealing.Moderate but brittle; verify support load and handling damage.25120 mmCold-service planning range; calculate with certified aged conductivity.Aluminium · Stainless steel · Continuous vapour retarderHighWater ingress and insulation chemistry/contaminants require a material-specific corrosion review.Verify active project edition
Polyurethane Foam (PUF)Low for intact closed-cell foam; joints and damaged vapour barrier govern system moisture.Moderate; verify density and creep under support load.25150 mmCold/cryogenic planning range; calculate condensation and vapour-barrier duty.Aluminium · Stainless steel · Continuous vapour retarderMediumHidden water at failed joints can remain trapped; fire and decomposition chemistry also require review.Verify active project edition
Polyisocyanurate (PIR)Low for intact closed-cell foam; verify aged properties and joint sealing.Moderate; verify density, creep and support inserts.25150 mmCold/cryogenic planning range; calculate heat gain and condensation control.Aluminium · Stainless steel · Continuous vapour retarderMediumVapour-barrier discontinuities and damaged cells can trap water at the pipe.Verify active project edition
FiberglassPorous system; facing and installation control water entry.Low; protect against crushing and use support inserts.25100 mmCommon planning range; verify product class and calculated duty.Aluminium · Stainless steel · All-service jacket for indoor useHighWet fibrous insulation and damaged jacketing can create persistent external corrosion conditions.C547-25
Elastomeric Foam (NBR)Low for intact closed-cell material; seal all seams and penetrations.Low; avoid compression that reduces thickness.1350 mmCondensation-control planning range; calculate for ambient humidity and line temperature.UV-resistant coating · Flexible protective covering · Metal jacket where detailed against compressionLowIntegral vapour resistance helps when seams remain sealed; concealed failures still require inspection.Verify active project edition
Mineral WoolPorous system; water performance is product and facing dependent. Keep dry.Low to moderate; use a load-bearing insert at supports.25100 mmCommon industrial planning range; calculate heat loss/surface temperature.Aluminium · Stainless steel · GRP/FRP weather barrierHighWet fibrous insulation can retain water against the pipe; seals and support details govern.C547-25
Cellular GlassHermetically closed-cell material with very low bulk absorption when intact; joints remain system weak points.High but brittle; distribute point loads and follow fabrication details.25150 mmBroad hot-to-cryogenic planning range; calculate condensation and heat gain/loss.Aluminium · Stainless steel · Vapour-barrier mastic/membraneLowLow bulk permeability helps, but open joints, damage and poor terminations can admit water.C552-22
Expanded PerliteWater-repellent grades exist, but cut surfaces and joints require weather protection.Moderate to high; verify grade-specific load and deformation.25100 mmHot-service planning range; calculate duty and support reaction.Aluminium · Stainless steelMediumRisk rises quickly where weather seals or cut joints allow water entry.Verify active project edition
Calcium SilicateAbsorptive inorganic material; weather barrier and sealed joints are essential.High relative to fibrous insulation; commonly considered near load-bearing locations.25100 mmHot-service planning range; calculate heat loss and support loads.Aluminium · Stainless steelHighWater ingress can be retained and concentrate contaminants at the metal surface.C533-17(2023)
Ceramic FiberPorous blanket; external service needs a robust weather barrier.Low; retain mechanically and avoid crushing.25100 mmHigh-temperature planning range; conductivity rises strongly with mean temperature.Stainless steel · High-temperature alloy jacketHighExternal water entry into porous blanket can hold moisture during shutdown/cycling.C892-19(2024)