ASTM A672 B60
UNS K02401ASTM A672 B60 material
Key Engineering Metrics
Instant specifications summary for ASTM A672 B60
General Specifications & Standard Data
ASTM A672Minimum Design Metal Temperature rules for impact testing exemption under ASME B31.3 paragraph 323.2.2.
Mechanical Properties
Room Temp (20°C / 68°F)Allowable Stress Data (ASME B31.3 Table A-1)
asme-b31-3Allowable Stress vs Temperature
ASME B31.3 / BPVC Section II Part D Reference Curve
| Temperature (°C) | Allowable Stress (MPa) | % of Room Temp Rating |
|---|---|---|
| 38 | 137.9 | 100% |
| 100 | 137.9 | 100% |
| 150 | 137.9 | 100% |
| 200 | 131.0 | 95% |
| 250 | 122.0 | 88% |
| 300 | 115.0 | 83% |
| 350 | 112.0 | 81% |
| 400 | 108.0 | 78% |
| 450 | 105.0 | 76% |
| 500 | 102.0 | 74% |
Chemical Composition (% Weight)
Heat & Product Analysis🛡️ Service Compatibility
Industry standard for crude oil, natural gas, LPG, and refined fuels up to 425°C.
Excellent for non-corrosive steam ≤425°C (800°F). Risk of graphitization above 425°C.
Standard for treated boiler feed & cooling water. Untreated water requires corrosion allowance.
Requires NACE MR0175 / ISO 15156 compliance, hardness ≤22 HRC, and HIC/SSC testing.
Risk of brittle failure below -29°C (-20°F). Use LTCS (A333 Gr. 6).
High uniform corrosion rate without lining or cathodic protection.
🔥 Welding & Heat Treatment
10°C min for wall thickness t ≤ 25mm; 95°C (200°F) preheat required for t > 25mm or C > 0.30% per ASME B31.3 Table 330.1.1.
Required if nominal wall thickness t > 19mm (0.75 in) per ASME B31.3 Table 331.1.1 (holding temp 600°C–650°C for 1 hr/in).
Exempt down to -29°C (-20°F) per ASME B31.3 Fig 323.2.2A Curve B. Impact test required if MDMT is lower.