NFPAPiping CodeUS / International

NFPA 24

Standard for the Installation of Private Fire Service Mains and Their Appurtenances

มาตรฐานการติดตั้งท่อเมนดับเพลิงเอกชนและอุปกรณ์ประกอบ

Organization
NFPA
Category
Piping Code
Edition
Region
US / International
Last Reviewed
2026-07-01
Status
reviewed
1

Overview

Installation of private fire-service mains and appurtenances supplying fire-protection systems.

2

Scope & Applicability

Applies To Industries

Fire ProtectionBuilding Services

Covers — installation of private fire-service mains and appurtenances: underground pipe materials, depth of cover, thrust restraint, valves, hydrants, and flushing/hydrostatic testing supplying fire-protection systems.

Does NOT cover (exclusions) — sprinkler systems → NFPA 13; standpipes → NFPA 14; fire pumps → NFPA 20; public water mains → the water utility/AWWA.

NFPA 24 covers the private buried fire mains between the supply and the building systems.

3

Key Requirements

NFPA 24 sets installation requirements for private fire mains:

  • Pipe & Depth — buried pipe materials and required cover.
  • Restraint — thrust restraint at bends, tees, and hydrants.
  • Valves & Hydrants — isolation valves and hydrant installation.
  • Flushing & Testing — flushing to remove debris and hydrostatic/leakage testing.
4

Technical Details

NFPA 24 governs private fire-service mains — the usually-buried piping, valves, and hydrants on private property that carry water from the supply to the building fire-protection systems. It covers pipe materials, depth of cover, thrust restraint at fittings, valves and hydrants, and the flushing and hydrostatic testing that verify the mains are clean and leak-tight.

It is the link between the public/private water supply and the systems designed to NFPA 13/14, fed as needed by an NFPA 20 fire pump. Because the mains are buried, restraint and testing before backfill are critical.

Engineering Note: Flush the mains thoroughly before connecting to the sprinkler/standpipe systems — construction debris left in a buried fire main can lodge in sprinkler orifices or valves and disable protection at the worst possible moment.

5

Engineering Notes

The private fire-service main standard — the (usually underground) piping, valves, and hydrants on private property that carry water from the supply to the building fire-protection systems (sprinklers, standpipes, hydrants). It covers pipe materials, depth/cover, thrust restraint, valves and hydrants, and the flushing and hydrostatic testing that ensure the buried mains are clean and leak-free before they are relied upon.

6

Source, Edition & Status

Publisher
NFPA
Industries
Fire Protection, Building Services
Last Reviewed
2026-07-01
Last Updated
2026-07-01
Verified By
Engineering content reviewer
Content Status
reviewed
Official Link
www.nfpa.org
Disclaimer: Disclaimer: This page provides a simplified engineering reference only. It is not a replacement for the official standard. For design, inspection, procurement, and construction, always refer to the latest official standard and the applicable project specification.