ASTMPlastic PipeUS / International

ASTM D2467

PVC Plastic Pipe Fittings, Schedule 80

ข้อต่อ PVC Schedule 80

Organization
ASTM
Category
Plastic Pipe
Edition
2020
Region
US / International
Last Reviewed
2026-07-01
Status
reviewed
1

Overview

Socket-type Schedule 80 poly(vinyl chloride) (PVC) pipe fittings for pressurized-liquid service compatible with the piping material.

2

Scope & Applicability

Applies To Industries

General IndustryChemical PlantWater Treatment

Covers — Schedule 80 socket-type PVC pipe fittings for pressurized-liquid service: materials, workmanship, dimensions, and burst pressure, matched to Schedule 80 PVC pipe.

Does NOT cover (exclusions) — the following are governed elsewhere:

  • Schedule 40 PVC fittings → ASTM D2466.
  • CPVC fittings for higher temperature → ASTM F439 / F438.
  • The pipe itself → ASTM D1785.
  • Solvent-cement material → ASTM D2564.

D2467 (Sch 80 socket) pairs with D1785 Sch 80 pipe; D2466 covers the lighter Sch 40 fittings.

3

Key Requirements

D2467 sets minimum requirements for Sch 80 PVC fittings:

  • Material — PVC cell classification consistent with Schedule 80 service.
  • Dimensions — socket dimensions and laying lengths matched to Sch 80 pipe.
  • Burst Pressure — minimum short-term burst by size.
  • Workmanship & Marking — freedom from defects and product identification.
4

Technical Details

ASTM D2467 specifies Schedule 80 socket-type PVC pipe fittings, matched to D1785 Schedule 80 pipe. The heavier Schedule 80 wall suits higher-pressure and industrial/chemical liquid service, and the socket connection is joined with PVC solvent cement to form a fused, monolithic joint.

Threaded PVC connections (Sch 80 only) are inherently weaker and prone to cracking if over-tightened, so socket-and-cement is preferred where possible. As with all PVC, chemical compatibility with the process fluid must be verified.

Engineering Note: Prefer solvent-cemented sockets over threaded PVC where you can, and never over-torque threaded PVC fittings — the notch-sensitive material cracks readily at the thread root under excess tightening or bending.

5

Engineering Notes

The Schedule 80 socket PVC fitting standard, matched to D1785 Sch 80 pipe. Schedule 80 (heavier wall) fittings are used for higher-pressure and industrial/chemical service; the socket is solvent-cemented to the pipe. Threaded PVC connections are weaker and limited to Sch 80 — over-tightening threaded PVC is a common cause of cracking. Confirm chemical compatibility of PVC with the fluid.

7

Source, Edition & Status

Publisher
ASTM
Edition Year
2020
Industries
General Industry, Chemical Plant, Water Treatment
Last Reviewed
2026-07-01
Last Updated
2026-07-01
Verified By
Engineering content reviewer
Content Status
reviewed
Official Link
www.astm.org
Disclaimer: Disclaimer: This page provides a simplified engineering reference only. It is not a replacement for the official standard. For design, inspection, procurement, and construction, always refer to the latest official standard and the applicable project specification.